類別
測試項目
測試條件
測試時間
樣品數
判定
參考標準
Life Stress Test |
HTGB |
Ta=150℃,100%VgsMax |
168/500 hrs |
77Pcs |
0/1 |
JESD22-A108 |
HTRB |
Ta=150℃,80%VdsMax |
168/500 hrs |
77Pcs |
0/1 |
JESD22-A108 |
Environment Stress Test |
Precondition |
30℃/60%RH+3 cycle reflow@260℃ (MSL3) |
192hrs |
77Pcs |
0/1 |
JESD22-A113 |
HTST |
Ta=150℃ |
168/500 hrs |
77Pcs |
0/1 |
JESD22-A103 |
TCT |
-65~150℃ |
500Cycle |
77Pcs |
0/1 |
JESD22-A104 |
UHAST |
130℃/85%RH/33.3psia |
96hrs |
77Pcs |
0/1 |
JESD22-A118 |
PCT |
121℃/100%RH/29.7psia |
96hrs |
77Pcs |
0/1 |
JESD22-A102 |
THT |
85℃/85%RH |
168/500 hrs |
77Pcs |
0/1 |
JESD22-A102 |
H3TRB |
85℃,85%RH,80% VDS, up to 100V |
168/500/1000hrs |
77Pcs |
0/1 |
JESD22-A101 |
IOL |
△Tj>100℃ |
Package dependent |
77Pcs |
0/1 |
MIL-STD-750 Method 1037 |